Specifications

Description

Multifunctional anesthesia working station
Features:  Anesthesia ventilator:  1) Ventilation modes: IPPV, PCV, manual  2) Display: 6.4'' TFT + High-luminance LED display  3) Monitoring parameters:      a) Minute volume      b) Tidal volume: 50-1,200ml, display tidal volume and respiratory rate for manual           mode  4) Airway pressure (Ppeak, Pmean)  5) Waveform: airway pressure waveform  6) Trend curve: full parameters 24-hour trend curve  7) Communication port: RS232  8) Parameters settings:      a) Respiratory rate: 4-60bpm      b) I/E ratio: 1:0.3, 1:0.5, 1:0.7, 1:1.0, 1:1.5, 1:2.0, 1:2.5, 1:3.0, 1:3.5, 1:4.0   9) Alarms parameters:       a) Upper airway pressure limit: 2-8KPa      b) Lower airway pressure limit: 0-2KPa      c) Upper and lower tidal volume limit      d) Upper and lower minute volume limit      e) Apnea      f) Power supply failure      g) Battery capacity insufficiency      h) Gas supply failure      i) Silence time for alarm: ≤120sec  10) Pressure limit for safety valve: 5.1-6KPa   11) Power supply: AC 220±22V, 50±1Hz  12) Backup battery: more than 2 hours    Anesthesia machine:  Flow meter (5-tube):  1) Low flow rate: 0.1-2L/min, 2.5-10L/min  2) High flow rate: 0.1-2L/min, 2.5-10L/min  3) Air: 0.1-10L/min  4) Oxygen failure protection device: when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off. During the process, O2 concentration remains above 25%  5) Safety performance:       a) Alarm for oxygen supply failure      b) Spill valve        d) Safety valve      e) O2 flush: 35-75L/min      f) Gas supplies:           i) O2: 0.3-0.4MPa          ii) N2O: 0.3-0.4MPa          iii) Air: 0.3-0.4MPa    Vaporizer:  1) Two ACM108 are equipped, one uses isoflurane, another uses enflurane as agent  2) These two can interlock,  3) Concentration range: 0.2-5% VOL  4) With function of flow and temperature compensation    Other information:  1) line AEP monitor  2) Display form: EL active display  3) Screen size: 12 x 9cm  4) Display viewing angle: 160 degrees maximum  5) Power supply: 100-240VAC, 50-60Hz, maximum 50VA  6) Operation temperature: 10-40°C  7) User interface: touch screen  8) Cable length: 3.0m  9) Electrodes: A-line electrodes  10) Headphones: A-line headphones  11) Backup battery: built-in, automatic charging, with working time of 30 minutes at         full charge  12) Parameter display: AAI, EMG, BS%, AEP, EEG  13) Trend curve: selectable view of 5, 30 or 60 minutes  14) Data output: RS232  15) Event marker: yes  16) Electrode alarm: yes  17) Electrode impedance monitoring system: yes  18) AAI alarm: the upper limit can be adjusted according to the needs  19) Information managing system in Anesthesia section  20) Pre-operation module:       a) Patient information      b) Pre-operation preparing information      c) Operation arrangement information  21) Operating module:      a) Recording all the clinical manifestation of the patient during the operation      b) Recording the monitoring data of the patient during the anesthetizing      c) Instant displaying the anaesthetizing recorder and the trend curve  22) After operation module:      a) Valuing the recovering condition after operation      b) Summarizing the anesthesia condition after operation      c) Transferring the patient  23) Monitor  24) Display: 12.1'' TFT LCD, or 15''CRT screen  25) Can choose the needed parameters of module monitoring  26) ECG HR  27) 2 channels ECG waveform  28) Abnormal HR and S-T segment analysis (optional)  29) PACE analysis  30) RESP RR  31) Respiration waveform  32) SpO2 SpO2, PR  33) SpO2 volume description diagram  34) NIBP NS, ND, NM  35) TEMPL T1, T2, TD  36) IBP CH2 SYS, DIA, MAP  37) CH2 SYS, DIA, MAP  38) CH3 SYS, DIA, MAP  39) CO TB  40) CO  41) CO2 EtCO2  42) InsCO2

Terms

FOB Price:
Minimum Order: 1pc
Port:
Payment Terms: T/T

ms yang's Products

You can verify ms yang using your contacts and professional networks.

Recently Viewed Products
Popular Products on Tradesparq